WARNING FOR INSTALLATION LOCATIONS
Do not install the heater where water, debris
or flammable vapors may get into the flue
terminal/opening. This may cause damage to
the heater and void the warranty.
Do not have the vent terminal/opening
pointing toward any opening into a building.
Do not locate your heater in a pit or location
where gas and water can accumulate.
Do not install this water heater under an
overhang less than 3 feet from its top or
eaves. The area under an overhang must be
open to three sides.
Do not install the water heater vent terminator
within 1 ft. in the USA of any air intake or
building opening, and with in 3 ft. in Canada
of any air intake or building opening (Refer to
p.13).
Avoid locating the water heater exhaust
opening near any air intake devices. These
fans can pick up the exhaust flue products
from the water heater and return them to the
building. This can create a health hazard.