The dark squares indicate the direction
the dipswitches should be set to.
Temperature Settings
TEMPERATURE SETTINGS
There are 4 preset temperatures that you can select from by changing the dipswitch settings on
the computer board.
The temperature has been preset at the factory to 122°F (50°C).
If you desire to change the set temperature with dipswitches, please refer to the diagram on
below. These temperatures are available: 113°F, 122°F, 140°F, 167°F.
140°F and 167°F are for heating applications only.
If you desire a hot water temperature other than the 4 preset settings, please purchase the
optional temperature remote controller (part No. TK-RE02).
With this optional TK-RE02 you can set the temperature from 99ºF to 167ºF with various
increments.
Please read the instructions carefully prior to installing the TK-RE02, as failure to do so could
damage the temperature controller and/or the water heater, which will void the warranty.
Turn off the power supply to the heater before changing the dipswitch settings.
Only change the switches with the dark squares. The dark squares indicate
which direction the dipswitch should be set to.
To change dipswitch settings for
temperatures, locate the bottom
left corner of the computer
board.
Dipswitches