Instruction Manual
28 Page
Installaon
Installaon Manual
HIGH-ALTITUDE INSTALLATIONS
Check the elevation where your water heater is installed. Set DIPswitches shown in the tables below
depending on the altitude.
NOTE:The dark squares indicate the direction the DIPswitches should be set to.
Only adjust the necessary switches.
Bank of DIPswitches
Computerboard
Indoormodel
Altitude
0to2,000ft.
(DEFAULT)
2,000to
3,000ft.
3,000to
5,000ft.
5,000to
7,500ft.
7,500to
10,100ft.
DIPswitches
No. 3 : OFF
No. 4 : OFF
No. 5 : OFF
No. 3 : OFF
No. 4 : ON
No. 5 : OFF
No. 3 : OFF
No. 4 : OFF
No. 5 : ON
No. 3 : OFF
No. 4 : ON
No. 5 : ON
No. 3 : ON
No. 4 : ON
No. 5 : ON
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
Outdoormodel
Altitude
0to2,000ft.
(DEFAULT)
2,000to
4,000ft.
4,000to
6,000ft.
Over6,000ft.
DIPswitches
Consult our
Technical
Services
at 1-877-
737-2840
No. 3 : OFF
No. 4 : OFF
No. 5 : OFF
No. 3 : OFF
No. 4 : OFF
No. 5 : ON
No. 3 : ON
No. 4 : OFF
No. 5 : ON
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10