User Guide
49 Page
Remote
Green
LED
Malfunction
description
Diagnosis
391*
Two Times Air-fuel ratio rod
failure
Check for connection/breakage of wires (Part #708)
and/or soot on the AFR rod (Part #108).
510
Six Times Abnormal main gas
solenoid valve
Check for connection/breakage of wires (Part #707)
and/or burn marks on the computer board (Part #701).
Check for signs of vent corrosion.
Check gas valve contacts and gas valve wire harness
connections for signs of rust or corrosion.
551
Six Times Abnormal gas
solenoid valve
Check for connection/breakage of wires (Part #707)
and/or burn marks on the computer board (Part #701).
Check gas valve contacts and gas valve wire harness
connections for signs of rust or corrosion..
611*
Four Times Fan motor fault Check for connection/breakage of wires, dust buildup
in the fan motor (Part #103) and/or burn marks on
the computer board (Part #701).
Check for frozen/corrosion of connectors (Part #103).
701*
One Time Computer board fault Check for connection/breakage of wires (Part #711).
711*
One Time Gas solenoid valve
drive circuit failure
Refer to the 111 and 121 error codes.
721*
Six Times False flame
detection
Check if there is leaking from heat exchanger (Part #401).
741
N/A Miscommunication
between the water
heater and remote
controller
Check the model type of the remote controller.
Inspect the connections between the water heater
and remote controller.
Check the power supply of the water heater.
751
N/A Miscommunication
between the water
heater and built-in
controller (Indoor
model only)
Inspect the connections between the water heater
and temperature controller.
Check the power supply of the water heater.
941
Five Times Abnormal exhaust
temperature (Indoor
model only)
Check to see of the exhaust temperature is higher
than 149°F (65°C).
991
Five Times Imperfect
combustion
Check if the gas type of the water heater matches
the gas supplied to it.
Inspect the environment around the water heater.
Determine how long the water heater has been
installed and match DIPswitches.
Check the altitude/elevation of the area of where
the water heater is installed.
Check if there is any blockage in the intake air and/
or exhaust.
If the water heater is installed as a direct-vent system,
check whether there is enough distance between the
intake air terminal and the exhaust terminal.
Check if there is grease and/or dirt in the burner (Part
#101) and the fan motor (Part #103), especially if the
water heater has been installed in a contaminated area
Check the DIP switches match gas type of the water
heater.
Check the manifold pressure at Max. and Min.
Check combustion chamber tube (part #117) to see
if it is clear and securely installed.
Troubleshoong
Owner's Guide
*These error code will be clear when water flow stops.