User Guide

26 Page
Installaon
Installaon Manual
-Clearances for sidewall terminaons-
Multiple Sidewall Terminations
An exhaust termination must be at least
1 ft (305mm) away from another exhaust
termination. An exhaust termination must
also be at least 2 ft (610 mm) away from
an inside corner. (If the adjacent wall is less
than 2 ft (610 mm) of length, the minimum
required distance away from the inside
corner will be equal to the length of that
adjacent wall.)
Multiple DV Sidewall Terminations
A direct vent (DV) termination must be
at least 1 ft (305 mm) away from other
direct vent terminations.
A direct vent termination must also be at
least 2 ft (610 mm) away from an inside
corner. (If the adjacent wall is less than
2 ft (610 mm) of length, the minimum
required distance away from the inside
corner will be equal to the length of that
adjacent wall.)
Ancipated Snow level
Exhaust
Terminaon
2
(610 mm)
min.
1
(305 mm)
min.
1
(305 mm)
min.
Inside
corner
Inside
corner
Ancipated Snow level
2
(610 mm)
min.
1
(305 mm)
min.
1
(305 mm)
min.
Combined
intake and
exhaust
terminaon
For direct vent sidewall
terminations that use two
separate penetrations for
the intake and exhaust, keep
the termination clearances
shown in the diagrams on
the right. The installation is
for only 3 inch and 4 inch
vent installations only.
Improper installation can result in carbon monoxide poisoning or death. Follow all local
and national codes in regards to proper termination clearances. In the absence of such
codes, the clearances below can be used as guidelines. Local codes supersede these
guidelines.
WARNING
<Case 2>
<Case 1>
Exhaust
termination
2 ft (610 mm)
min.
Exhaust and/or direct
vent sidewall terminations
should be at least 2 ft (610
mm) away from an opposite
surface/wall. Do not place
the termination directly in
front of an opening into a
building.
Exhaust
Intake
1 (305 mm)
min.
Exhaust
Intake
0.5 ft
(159 mm)
min.
0.5 ft
(159 mm)
min.
Exhaust
Intake
1 
(305 mm)
min.
Exhaust
Intake
0.5 ft
(159 mm)
min.
0.5 ft
(159 mm)
min.