Ventconneconsfordirectvent
4" stainless steel
vent straight pipe
Exhaust vent
collar (Female)
Intake vent collar
(Female)
4" stainless steel
vent straight pipe
Exhaust vent
collar (Female)
4" stainless steel
vent straight pipe
Intake vent collar
(Female)
4" elbow with
bird screen
1. Connect a 4" stainless steel vent straight pipes
directly on the exhaust vent collar of the water
heater.
2. Connect a 4" elbow directly on the intake vent
collar of the water heater.
Connect 4" stainless steel ventstraight pipes
directly on the exhaust/intake vent collar of the
water heater.
Ventconneconsforsinglevent
-DIP switch settings for vent length-
Typicalinstallaonsusingstainless steel vents
WARNING
• Adjust the appropriate DIP switches according to size and vent length as shown
below. DO NOT adjust the other DIP switches.
• Turn off the power supply to the water heater before changing the DIP switch settings.
• Failure to observe these warnings could lead to carbon monoxide poisoning or death.
VercalInstallaon
Roof

Fire stop
Rain cap
HorizontalInstallaon
Wall
Sidewall vent

Hanger
Hanger
For details of the optional items, refer to the Installation manual for each optional item.
4inchventinstallaon
Vent length Two-pipe and Single pipe
5 to 50 ft
(1.5 to 15.2 m)
(DEFAULT)
ON
No. 6 : ON
No. 7 : OFF
51 to 100 ft
(15.3 to 30.5 m)
ON
No. 6 : OFF
No. 7 : OFF
Bank of DIP switches
Computer board