User Guide
19 Page
For details of the optional items, refer to the Installation manual for each optional item.
For clearance information, refer to pp. 25 to 27.
Single vent with room-air intake
Termination
Hanger
1. Connect a 3" elbow directly on the intake vent
collar of the water heater.
2. Connect a 3" x 2" reducer directly on the
exhaust vent collar of the wateheater. Make
sure the couplings engage the o-rings installed
in the intake and exhaust vent collars
3. Connect a 2" straight pipe to the reducer.
Vent connections for single vent
*The bird screen that fits into the 3 inch elbow is
supplied with the indoor water heater.
* 3" elbow with bird
screen
Intake vent
collar
(Female)
3"x2" reducer
2" straight pipe
Exhaust vent
collar (Female)
-DIP switch settings for vent length-
Typicalinstallaonsusing PVC, CPVC, ABS, or polypropylene vent
WARNING
• Adjust the appropriate DIP switches according to vent size and vent length as
shown below. DO NOT adjust the other DIP switches.
• Turn off the power supply to the water heater before changing the DIP
switch settings.
• Failure to observe these warnings could lead to carbon monoxide poisoning
or death.
2inchventinstallaon
Vent length Single vent
5 to 6.5 ft
(1.5 to 2.0 m)
OFF
ON
1 2 3 4 5 6 7 8 9 10
No. 6 : ON
No. 7 : ON
Bank of DIP switches
Computer board
Installaon
Installaon Manual