TRGSS01713
All dimensions are in inches.
15-150 psi Water Pressure. 40 psi or above is recommended for maximum flow.
*Current numbers based on factory testing; 0.5 gpm required for activation; 0.4 gpm required for continuous fire after initial ignition.
Indoor models are certified from sea level to 10,100 ft. elevations.
In accordance with ANSI Z21.10.3, CO emission does not exceed 400 PPM for normal input.
The manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligation.
MODEL NUMBER TYPE
GAS CONSUMPTION INPUT INLET GAS PRESSURE
UEF MAXIMUM GPM*
MINIMUM BTU/H MAXIMUM BTU/H MINIMUM W.C. MAXIMUM W.C.
Indoor Models
T-H3M-IN-N
Natural 15,000 120,000 4.0 10.5 0.90 6.6
T-H3M-IN-P
Propane 13,000 120,000 8.0 14.0 0.90 6.6
Outdoor Models
T-H3M-OS-N
Natural 15,000 120,000 4.0 10.5 0.91 6.6
T-H3M-OS-P
Propane 13,000 120,000 8.0 14.0 0.91 6.6
MODEL NUMBER HOT/COLD CONNECTIONS GAS CONNECTION
DIMENSIONS IN INCHES
APPROX SHIPPING
WEIGHT (LBS)
HEIGHT WIDTH DEPTH
Indoor Models
T-H3M-IN-N
3/4” NPT 1/2” NPT 22-7/8 13-7/8 10-13/16 54
T-H3M-IN-P
3/4” NPT 1/2” NPT 22-7/8 13-7/8 10-13/16 54
Outdoor Models
T-H3M-OS-N
3/4” NPT 1/2” NPT 22-7/8 13-7/8 10-13/16 52
T-H3M-OS-P