Install Instructions

Installation
10Page
Improperventingofthisappliancecanresultinexcessivelevelsofcarbonmonoxide
whichcanresultinseverepersonalinjuryordeath.
Wheninstallingtheventsystem,allapplicablenationalandlocalcodesmustbe
followed.Ifyouinstallthimbles,firestopsorotherprotectivedevicesandthey
penetrateanycombustibleornoncombustibleconstruction,besuretofollowall
applicablenationalandlocalcodes.
INSTALLATIONFORDIRECTVENTINDOORMODELS
TheDirectVent Indoor modelsareequippedwithathermistorandhilimitswitchfor the exhaustgas,
detectingexcesstemperatureswithintheflueandenablingtheunittosafelystopoperationsifneeded.
These components are always monitoring exhaust gas conditions in order to prevent heat damage to
PVC(Plastic)ventingifPVCisused.
If the exhaust gas temperature exceeds 140°F, these components will enable the unit to safely stop
operations.(For the Outdoor model, these components are not available since there’s no exhaust
ventingrequ ired.)
TheDirectVentIndoormodelrequiresa
4” makeup intake air supply pipe. The
intakepipemustbesealedairtight.
AirsupplypipecanbemadeofABS,PVC,
galvanized steel, corrugated stainless
steel,orCategorylll/IVstainlesssteel.
Sidewallventingisrecommendedforthe
Direct Vent Ind oor model. Vertical
venting(rooftermination)isacceptable.
The manufacturer recommends
running the exhaust vent and the
intakepipeasparallelasp ossible.
ThePVCadaptorisusedtomake the
connection between the Direct Vent
Indoor model vent collar and PVC
ventpipeeasierand
formaintenance
purposes.
VENTINGINSTRUCTIONS
General
TheDirectVentIndoormodelsmustbeventedinaccordancewiththesection“VentingofEquipment"
of the latest edition of the National Fuel Gas Code: ANSI Z223.1/NFPA 54 in the United States and/or
Section 7 of the CAN/CSA B149.1 Natural Gas and Propane Installation Code in
Canada, as well as
applicablelocalbuildingcodes.
TheuseofventingmaterialsapprovedforCategoryIII/IVappliance sisrecommendedwheneverpossible.
However,theDirectVentIndoormodelsmayalsobeventedwithplasticpipematerialssuchasPVC.For
details,pleasereferto theExhaustVent(PVC Vent)sectiononp.11.VentinstallationsinCanadawhich
utilize
plasticventsystemsmustuseventingthatcomplieswithULCS636.
WARNING
Top12”
Side3”
Back0.5”
Side3”
Front4”
(24”Recommended
forMaintenance)
Bottom12”
Keeptheclearance s.