Install Instructions

Installation
25Page
InanEasyLinksystem,thepumpmustbeconnectedtothe“Pumpconnector”in
the“MASTERunit”only.Ifthepumpisconnectedtoanyofthe“SLAVEunits”,the
pumpwillnotwork.
PUMPCONTROLCONNECTION
The TH2DV/TH2OS can be used to control a recirculation pump. Proper pump control helps to
preservethe lifeof thesystem and saves energy as well: The TH2DV/TH2OSpumpcontrol port is a
“normally open dry contact”, and therefore needs additional components
to properly control a
recirculationpump.Tocontrolarecirculationpump,connectthepumptothe“Pumpconnector”inthe
TH2DV/TH2OSas shownin the diagrambelow. (In an EasyLinksystem, connect thepumpONLY to
theMASTERunit.)Thepumpistobeconnected
usingsuitablerelaysshowninthediagrambelow.
Pleasemakesuretherelaysareproperlyratedfortherecirculationpump.
UsingtheTH2DV/TH2OS’sinternalthermistorsasatemperaturecontrol,therecirculationpumpwill
onlyturnonwhenrecirculationisneeded.
CAUTION
Connecttothis“Pumpconnector”.
Recirculation
pump
Powersupply
forpump
AC120V
AC220Vetc
Powersupply
forrelay
ThesecomponentsareNOTincludedwiththeTH2DV/TH2OS
andareexternaltotheunit.Theymustbeacquiredseparately.
Thermal
relay
AC120V
AC220Vetc
forrelay