Install Instructions
37 Page
TEMPERATURE SETTINGS
-Set temperature-
TEMPERATURE TABLE OF REMOTE CONTROLLER
Normal Operaon
Owner's Guide
°F 100 105 110 115 120* 125 130 135 140
°C 38 40 43 45 50* 52 55 57 60
a) For 110U (T-KJr2U) and 310U (T-K4U) models
°F 100 105 110 115 120* 125 130 135 140 145 150 155 160
°C 38 40 43 45 50* 52 55 57 60 63 65 68 70
b) For 510U (T-D2U) model
*Factory setting (Default): 120 °F
Operation Screen
1.
Turn on the 120 VAC power supply to the unit (the water heater or
the multi-unit controller).
2.
Press the "ON/OFF" button on the controller in order to turn the controller
on.
3.
When ON, the STAND BY LED is lit.
4.
It shows the set temperature on its display as shown in the picture on the
right. (EX.: 120 °F)
5.
Press the "HOT" button or the "COLD" button to set the temperature setting
of the unit.
Increasing temperature from 120 °F (50 °C) to 125 °F (52 °C):
1. The water heater must be in Stand By to increase the temperature.
2. Press the "HOT" button to set 120 °F (50 °C).
3. Press and hold the "INFO" button and the "HOT" button for at least 3
seconds. The remote will emit a beep and change to 125 °F (52 °C).
4. Press the "HOT" button to set up to 140 °F (60 °C).
Increasing temperature above 140 °F (60 °C)
-510U (T-D2U) model only-:
1. The water heater must be in Stand By to increase the temperature.
2. Press the "HOT" button to set 140 °F (60 °C).
3. Press and hold the "INFO" button and the "HOT" button for at least 3
seconds. The remote will emit a beep and change to 145 °F (63 °C).
4. Press the "HOT" button to set up to 160 °F (70 °C).
(EX.: 120 °F)