Install Instructions
12 Page
HIGH-ALTITUDE INSTALLATIONS
Check the elevation where your water heater is installed. Set DIPswitches shown in the table below
depending on the altitude.
Bank of DIPswitches
110U (T-KJr2U) and 310U (T-K4U) models
Computer board
WARNING
DO NOT adjust any DIPswitches on the upper bank for the 510U (T-D2U)
model.
NOTE: The dark squares indicate the direction the DIPswitches should be set to.
Lower bank of DIPswitches
510U (T-D2U) model
Computer board
Installaon
Installaon Manual
Outdoor models
0 to 2,000 ft.
(DEFAULT)
2,000 to
4,000 ft.
4,000 to
6,000 ft.
110U (T-KJr2U) and
310U (T-K4U) models
No. 3 : OFF
No. 4 : OFF
No. 5 : OFF
No. 3 : OFF
No. 4 : OFF
No. 5 : ON
No. 3 : ON
No. 4 : OFF
No. 5 : ON
510U (T-D2U) model
(Lower bank of
DIPswitches)
No. 2 : OFF
No. 3 : OFF
No. 4 : OFF
No. 2 : OFF
No. 3 : OFF
No. 4 : ON
No. 2 : ON
No. 3 : OFF
No. 4 : ON
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6
OFF
ON
1 2 3 4 5 6
OFF
ON
1 2 3 4 5 6
Indoor models
0 to 2,000 ft.
(DEFAULT)
2,000 to
3,000 ft.
3,000 to
5,000 ft.
5,000 to
7,500 ft.
7,500 to
10,100 ft.
110U (T-KJr2U) and
310U (T-K4U) models
No. 3 : OFF
No. 4 : OFF
No. 5 : OFF
No. 3 : OFF
No. 4 : ON
No. 5 : OFF
No. 3 : OFF
No. 4 : OFF
No. 5 : ON
No. 3 : OFF
No. 4 : ON
No. 5 : ON
No. 3 : ON
No. 4 : ON
No. 5 : ON
510U (T-D2U) model
(Lower bank of
DIPswitches)
No. 2 : OFF
No. 3 : OFF
No. 4 : OFF
No. 2 : OFF
No. 3 : ON
No. 4 : OFF
No. 2 : OFF
No. 3 : OFF
No. 4 : ON
No. 2 : OFF
No. 3 : ON
No. 4 : ON
No. 2 : ON
No. 3 : ON
No. 4 : ON
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6
OFF
ON
1 2 3 4 5 6
OFF
ON
1 2 3 4 5 6
OFF
ON
1 2 3 4 5 6
Altitude
DIPswitches
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6
Installation altitude
The maximum certified
or allowable installed
altitude is 10,100 ft. for
indoor models and 6,000 ft.