User Guide

36 Page
Normal Operaon
Owner's Guide
How to change to the High temperature mode
1. Turn off power to the remote controller by pressing the “ON/OFF” button. (Lamp is OFF to indicate
that power is off.)
2. Simultaneously press and hold both the “HOT” and “COLD” buttons for at least 5 seconds. And then
make sure “1” (or “0”) is displayed on remote controller.
3. Press the “TIME” button. Make sure “OFF” and “F1” are displayed on remote controller.
4. Press the “INFO” button. After, make sure “OFF” blinks.
5. Press the “HOT button or the “COLD button to set display to on”.
6. Simultaneously press both the “BUZZER” button and the “INFO” button to fix the setting. Make sure
the display is no longer blinking.
7. Press the ON/OFF button to finish the setting.
8. Turn on power to the remote controller by pressing the “ON/OFF” button again. (Lamp is ON to indicate
that power is on.)
I N
OUT
FLOW
L/M
G/M
I N
OUT
FLOW
L/M
G/M
“1” is displayed for single unit.
I N
OUT
FLOW
L/M
G/M
“0” is displayed for Easy-Link System.
I N
OUT
FLOW
L/M
G/M
"OFF" blinks.
I N
OUT
FLOW
L/M
G/M
"ON" blinks.
I N
OUT
FLOW
L/M
G/M
"ON" stops blinking.
C) Other features of the remote controllers
• Features available on 9007666005 (TK-RE02) and 9007603005 (TM-RE30)
<Buzzer operation>
If there is a problem with the water heater, the remote controller will sound a buzzer and display the error
code to inform you the source of the problem.
You can stop the buzzer by pressing : "any button" for 9007666005 (TK-RE02)
"Buzzer button" for 9007603005 (TM-RE30).
For details on the error code, refer to p. 43.
NOTE: If you want to disable the buzzer operation, press and hold the "BUZZER" button for 3 seconds or
longer. (9007603005 (TM-RE30) only.)
<Information mode>
You can get some information about the water heater condition by pressing :
"INFORMATION" button for 9007666005 (TK-RE02)
"INFO" button for 9007603005 (TM-RE30)
During the information mode, the information will be rotated by pressing the "INFORMATION" or "INFO"
button as follows:
Inlet water temperature Outlet water temperature
Waterow Finishinformaonmode