Malfunction
description
Diagnosis
Red
LED
RE02 RE30
N/A N/A 441
FlowSensor
Failure(EasyLink
Systemonly)
Check for co nnection/breakage of wires and/or debris
ontheflowsensorimpeller.(Part#402,717)
Six
Times
51 510
AbnormalGas
SolenoidValve
Check for connection/breakage of wires (Part #708)
and/orburnmarksonthecomputerboard(Part#701).
Six
Times
55 N/A
AbnormalMain
GasValve
Checkforconnect ion/breakageofwires(Part#708)
and/orburnmarksonthecomputerboard(Part#701).
Four
Times
61 611
FanMotorFault
Checkforconnect ion/breakageofwires,dustbuildupin
thefanmotor(Part#103)and/orburnmarksonthe
computerboard(Part#701).
Checkforfrozen/corrosionofconnectors(Part#103).
N/A N/A 651
Flowadjustment
ValveFault
(EasyLink
Systemonly)
Inspect the flow adjustment valve (Part #402), for
connection/breakageofwires(Part#718),lockedmotor
driveduetoscalebuildup,and/orwaterleakage.
One
Time
70 701
Computerboard
Fault
Check for connection/breakage of wires (Part #714)
and/orburnmarksonthecomputerboard(Part#701).
Checkthepowersupplyofthewaterheater.
Six
Times
72 721
FalseFlame
Detection
Forindoormodels,checkifcondensatedrainisinstalled
ontheventcollarofthewaterheater.
Checkifthereisleakingfromheatexchanger(Part
#401).
N/A 74 741
Miscommunication
betweenWater
heaterandremote
controller
Checkthemodeltypeoftheremotecontroller.
Inspect the connections between the water heater and
remotecontroller.
Checkthepowersupply ofthewaterheater.
N/A N/A
761
Miscommunication
inEasyLinksy stem
Check if the connections between the parent unit and
thechildunitsarecorrect.Refertop.24to27.
Five
Times
99 991
Imperfect
combustion
Checkthegastypeofthewaterheater.
Inspecttheenvironmentaroundthewaterheater.
Determinehowlongtheunithasbeeninstalled.
Checkthealtitude/elevationoftheareaofwherethe
waterheaterinstalled.
Checkifthereisanyblockageintheintakeairand/or
exhaust.
Ifthewaterheaterisinstalledasadirectventsystem,
checkwhetherthereisenoughdistancebetweenthe
intakeairterminalandtheexhaustterminal.
Checkifthereisgreaseand/ordirtintheburner(Part#
101)andthefanmotor(Part#104),especiallyifthe
waterheaterhasbeeninstalledinacontaminatedarea.