Manual

NormalOperation
35Page
Onlypipeswithinthewaterheaterareprotectedbythefreezeprotection
system.Anywaterpipes(hotorcold)locatedoutsidetheunitwillnotbe
protected.Properlyprotectandinsulatethesepipesfromfreezing.
HouseholdFlowRates
TakenfromUPC2006
TakenfromUPC2006
FLOW
Theflowratethroughthewaterheaterislimitedtoa
maximumof6.6GPMfortheTKJr2IN/OS,8.0GPMfor
theTK4IN/OS,and10.0GPMfortheTD2IN/OS.
Thetemperaturesetting,alongwiththesupply
temperatureofthewaterwilldeterminethe
flowrate
outputoftheunit.
Pleaserefertothetemper aturevs.gallonsperminute
chartonp.4849todeterminethelikelyflowrates
basedonyourlocalgroundwatertemperatureandyour
desiredoutletwatertemperature.
BasedontheUnitedStatesDepartmentofEnergyme thod
oftestingwaterheateroutput,thewater
heaterisratedforgallonsperhour(GPH)orgallonsperminute(GPM)forNaturalGasandPropane,
whenraisingthewatertemperatureby77°F(from58°Fto135°F).Seethediagrambelow.
Refertothetabletothetop
rightfortypicalhouseholdplumbingfixtureflowratestodetermine
whatthewaterheatercandoinahouseholdapplication.
FREEZEPROTECTIONSYSTEM
Thisunitcomesequippedwithheatingblockstoprotectitagainstdamagesassociatedwithfreezing.
Forthisfreezeprotectionsystemtooperatethere hastobeelectricalpowertotheunit.Damageto
the heat exchanger caused by freezing temperatures due to power loss is not covere d under the
warranty.Incaseswherepowerlossescanoccur,considertheuseofabackuppowersupply.
The freezeprotectionsystemwillactivatewhenthesurroundingand/or outsidetemperaturesdrop
below36.5°F(2.5°C).
FortheTKJr2IN,TK4IN,andTD2INmodels:
In any areas subject to freezing temperatures, the manufacturer highly recommends an
indoor installation with an indoor model.In such an installation, freezing issues can only
occur if cold air enters through the venting into the heat exchanger, whether by negative
pressureswithintheinstallationlocationorbystrongoutsidewinds.
Themanufacturer also highly recommends theuse of aback flow ventdamper tominimize
theamountofcoldairenteringthroughtheexhaustventingwhenthewaterheaterisoff.
It is the installer’s responsibility to be awareof freezing issues and take all preventative measures.
themanufacturerwillnotberesponsibleforanydamagetotheheatexchangerasaresultoffreezing.
Ifyouwillnotbeusingyourheaterforalongperiodoftime:
1.
Completelydraintheunitofwater.Refertop.36.
2. Disconnectpowertoyourheater.
Thiswillkeepyourunitfromfreezingandbeingdamaged.
Appliance/Use FlowRate(GPM)
LavatoryFaucet 1.0
BathTub 4.010.0
Shower 2.0
KitchenSink 1.5
Dishwasher 1.5
Washingmachine 4.0
TKJr2IN TKJr2OS TK4IN TK4OS TD2IN TD2OS
GPH GPM GPH GPM GPH GPM GPH GPM GPH GPM GPH GPM
NaturalGas 180 3.0 180 3.0 246 4.1 246 4.1 252 4.2 252 4.2
Propane 180 3.0 180 3.0 246 4.1 246 4.1 252 4.2 252 4.2