Manual

NormalOperation
33Page
Flowratetoactivatethewaterheater:0.75gallonperminute
Flowratetokeepthewaterheaterrunning:0.4gallonperminute
HotWatertemperaturesover125°F(52°C)cancausesevereburnsinstantlyor
deathfromscalding.
Theoutlethotwatertemperatureofthewaterheaterisfactory
setat122°F(50°C).
Feelthewatertemperaturebeforebathingorshowering.
NORMALOPERATION
GENERAL
1. Openahotwatertap.*
2. Mixcoldwaterwiththehottoget
thecorrecttemperaturewater.
3. Closethehotwatertap.
*Ifaremotecontrollerinstalled,turntheremotecontrollerONbypressingthepowerON/OFFbutton
ontheremotecontrollerandthensetthetemperaturebypressingtheHOT/COLDbuttons before
openingahotwatertap.Thetemperatureisdisplayedwhentheremotecontro lleristurnedON.
TEMPERATURESETTINGS
Withoutremotecontroller‐
Depending on the model, there are 4 or 8 temperatures that you can select from by changing the
dipswitchsettingsonthecomputerboardwithouttheremotecontroller.Seethetablebelow.
Model Temperaturesavailable
TKJr2IN/TKJr2OS,
TK4IN/TK4OS
113°F 122°F 131°F 140°F
TD2IN
TD2OS
104°F 113°F 122°F 131°F 140°F 158°F 176°F 185°F
Fordetaileddipswitchsettingsforeachtemperature,refertothenextpage.
Thetemperaturehasbeenpresetatthefactoryto122°F(50°C).
If temperatures other th an the ones listed above are require d, the remote controller can
provideseveralmoretemperatureoptions.Refertop.9foralist
ofavailabletemperatureson
theremotecontroller.
This water heater is an ondemand, tankless water heater designed to efficiently supply
endlesshotwaterwithoutreferencetotemperaturesettings.
NOTICE
WARNING