DONOTadjustanydipswitchesontherightbankfortheTD2IN/OS
models.
Thedarksquaresindicatethedirectionthedipswitchesshouldbesetto.
Dipswitches
HIGHALTITUDEINSTALLATIONS
Checktheelevationwhereyourwaterheaterisinstalled.Setdipswitchesshowninthetablebelow
dependingonthealtitude.
Altitude
0to2,000ft
(DEFAULT)
2,000to4,000ft
4,000to6,000ft Over6,000ft
SwitchNo.3 OFF
ON
OFF
Consult
our Technical
Services
Department
at1888‐
8825244
SwitchNo.4 OFF
OFF
ON
Altitude
0to2,000ft
(DEFAULT)
2,000to4,000ft
4,000to6,000ft Over6,000ft
SwitchNo.4 OFF
ON
OFF
Consult
our Technical
Services
Department
at1888‐
8825244
SwitchNo.5 OFF
OFF
ON
TKJr2IN/OS&TK4IN/OS