Manual
T-D2-IN
S-001-TD2IN-0
The Manufacturer reserves the right to change or disconnue the design, drawing and/or specificaon of its products without noce at anyme.
Flow Rate vs. Temperature Rise
Pressure Loss
Flow Rate (gpm)
Temperature Rise (
°
F)
Pressure Loss (psi)
Head Feet
Installaon Type
Electric Consumpon
Fuel NG LP
Min 11,000 BTU/h Min 11,000 BTU/h
Max 199,000 BTU/h Max 199,000 BTU/h
Energy Factor 0.83 0.82
Min 5.0" W.C. Min 8.0" W.C.
Max 10.5" W.C. Max 14.0" W.C.
Flow Rate Max 10.0 GPM
40 psi or above recommended for maximum Flow
Without Remote (Dipswith Seng)
104°F, 113°F, 122°F (Default), 131°F, 140°F, 158°F,
176°F, 185°F
With TM-RE30 Temperature Remote
Controller : 99°F to 185°F,
122°F Default Factory Seng
99°F, 100°F, 102°F, 104°F, 106°F, 108°F, 109°F, 110°F,
111°F, 113°F, 115°F, 117°F, 122°F (Default), 131°F,
140°F, 158°F, 167°F, 176°F and 185°F
Temperature Sengs
Indoor and Direct Vent Only
120 VAC ; Standby: 0.05 A, Operaon: 0.75 A, Freeze-Protecon: 0.93 A
Gas Consumpon Input
Inlet Gas Pressure
Water Pressure
15-150 psi
Pressure Only Relief Valve Required
(Min 200,000 BTUs. 150 psi)