Installation Sheet
45 Page
Troubleshoong
Owner's Guide
*These error codes will be cleared when water flow stops.
Error
code
Malfunction
description
Diagnosis
611*
Fan motor fault Check for connection/breakage of wires, dust buildup in the fan motor
(Part #416) and/or burn marks on the computer board (Part #701).
Check for frozen/corrosion of connectors.
631
Abnormal external
pump
Check whether the pump connected to center computer board works
properly.
651*
Flow adjustment valve
fault
Inspect the flow adjustment valve for connection/breakage of wires,
locked motor drive due to scale buildup, and/or water leakage.
Visual inspection of PCB: connection/breakage of wires and/or burn
marks on the computer board.
661*
Water control valve
fault
(Bypass function)
Inspect the flow adjustment valve, for connection/breakage of wires,
locked motor drive due to scale buildup, and/or water leakage.
Visual inspection of PCB: connection/breakage of wires and/or burn
marks on the computer board.
681
Abnormal external fan
motor
Check whether the external fan motor connected to center computer
board works properly.
701*
Computer board fault
Check for connection/breakage of wires and/or burn marks on the
computer board.
Check the power supply of the water heater.
721*
False flame detection For indoor models, check if condensate drain is installed on the vent
collar of the water heater.
Check if there is leaking from the heat exchanger (Part #401).
741
Miscommunication
between
water heater and
remote controller
Check the model type of the remote controller.
Inspect the connections between the water heater and remote con-
troller.
Check the power supply of the water heater.
761
Miscommunication
in Easy-Link
System
Check if the connections between the parent unit and the Child units
are correct. Refer to p. 28.
Check that the power is on to all Child units.
991*
Imperfect
combustion
Make sure that the gas type of the water heater matches the gas
supplied to it.
Inspect the environment around the water heater. Determine how
long the unit has been installed.
Check if there is any blockage in the intake air and/or exhaust.
If the water heater is installed as a direct-vent system, check whether
there is enough distance between the intake air terminal and the
exhaust terminal.
Check if there is grease and/or dirt in the burner (Part #101) and
the fan motor (Part #416), especially if the water heater has been
installed in a contaminated area.
Make sure that the DIP switches match the gas type of unit.
Check the manifold pressure at Max. and Min.
Check the proportional gas valve hose.