Installation Sheet
43 Page
Troubleshoong
Owner's Guide
-Error code display-
7-Seg LED on the center computer board:
A three digit error code will be displayed on the 7-Seg LED one number at a time.
Remote controller:
A three digit error code will be displayed on the screen.
When the right and/or left combustion section has an error code, the red LED next to the 7-Seg LED
on the center computer board will flash to indicate which combustion section has the error code.
Refer to the graphics above.
Example: If your unit has the “321” error code (which signifies an inlet thermistor failure):
7-Seg LED
I N
OUT
FLOW
L/M
G/M
Remote
-Easy-Link System-
The 7-Seg LED on the PARENT unit displays a 5-digit number to signify which unit in the Easy-Link system has the
error, and what the error code is. The 7-Seg LED displays the number one digit at a time. The remote controller
100112155 (TM-RE30) (if installed) displays a 3-digit number which also signifies which unit has the error, and what
the error code is. The unit that has the error in an Easy-Link system will display the error code on its 7-Seg LED in
exactly the same way as if it were only a Single Unit. When the right and/or left combustion section has an error
code, the red lamp next to the 7-Seg LED on the center computer board will flash to indicate which combustion
section has the error code. Refer to the diagram below.
Example: If Unit #2 has the “321” error code (inlet thermistor)
The 7-Seg LED on the PARENT unit will display “3”...“2” “1” “0” “2”, displaying only one digit at a time. The first
3 numbers indicate the error code. The last two numbers indicate that Unit #2 has the error.
The remote controller, however, will display
“232” on its screen. The first “2” indicates
that Unit #2 has the error. The “32” indicates
the first two digits of the “321” error code.
The 7-Seg LED on Unit #2 will display “3”. “2”.
“1”, just like in the Single Unit example.
ERROR CODES
-General-
The units have self-diagnostic functions for safety and convenience when troubleshooting.
If there is a problem with the installation or the unit, the error code will be displayed on the 7-Seg LED on the
center computer board and remote controller (if it is installed.)
Consult the table on the following pages for the description of each error code.
Upper bank of DIP
switches
Lower bank of DIP
switches
7-Seg
LED
First red lamp:
an error code.
Second red lamp:
an error code.
Remote controller (Optional)
100112155(TM-RE30)
Unit#1
PARENT
Unit#2
CHILD
Unit#3
CHILD
Unit#4
CHILD
Remote
Controller
“3”..”2”..”1”..”0”..”2”
“3”..”2”..”1"