Datasheet
 TS78L00 Series 
3-Terminal 100mA Positive Voltage Regulator 
  5/12  Version: A07 
TS78L15 Electrical Characteristics 
Vin=23V, Iout=40mA, 0
o
C≤Tj≤125
o
C, Cin=0.33uF, Cout=0.1uF; unless otherwise specified.) 
Parameter 
Symbol 
Test Condition 
Min 
Typ 
Max 
Unit 
Tj=25
o
C 
14.42 
15 
15.60 
Output voltage 
Vout 
17.5V≤Vin≤30V, 
5mA≤Iout≤100mA 
14.28 
15 
15.75 
V 
Line Regulation 
REGline 
Tj=25
o
C 
11.5V≤Vin≤24V 
Iout=40mA 
-- 
150 
30 
5mA≤Iout≤100mA 
-- 
50 
150 
Load Regulation 
REGload 
Tj=25
o
C 
5mA≤Iout≤40mA 
-- 
25 
75 
mV 
Quiescent Current 
 Iq 
Iout=0, Tj=25
o
C 
-- 
3 
6.6 
20V≤Vin≤30V 
-- 
-- 
1.5 
Quiescent Current Change 
ΔIq 
5mA≤Iout≤40mA 
-- 
-- 
0.1 
mA 
Output Noise Voltage 
 Vn 
10Hz≤f≤100KHz, Tj=25
o
C 
-- 
90 
-- 
µV 
Ripple Rejection Ratio 
RR 
f=120Hz, 18V≤Vin≤28V 
34 
39 
-- 
dB 
Voltage Drop 
 Vdrop 
Iout=100mA, Tj=25
o
C 
-- 
1.7 
-- 
V 
Peak Output Current 
 Io peak 
Tj=25
o
C 
-- 
0.15 
-- 
A 
Temperature Coefficient of  
Output Voltage 
ΔVout/ ΔTj 
Iout=5mA, 0
o
C≤Tj≤125
o
C 
-- 
-1.3 
-- 
mV/ 
o
C 
TS78L18 Electrical Characteristics 
Vin=27V, Iout=40mA, 0
o
C≤Tj≤125
o
C, Cin=0.33uF, Cout=0.1uF; unless otherwise specified.) 
Parameter 
Symbol 
Test Condition 
Min 
Typ 
Max 
Unit 
Tj=25
o
C 
17.30 
18 
18.72 
Output voltage 
Vout 
21V≤Vin≤33V, 
5mA≤Iout≤100mA 
17.14 
18 
18.90 
V 
Line Regulation 
REGline 
Tj=25
o
C 
21≤Vin≤33V 
Iout=40mA 
-- 
180 
360 
5mA≤Iout≤100mA 
-- 
60 
180 
Load Regulation 
REGload 
Tj=25
o
C 
5mA≤Iout≤40mA 
-- 
30 
90 
mV 
Quiescent Current 
 Iq 
Iout=0, Tj=25
o
C 
-- 
3 
6.5 
21V≤Vin≤33V 
-- 
-- 
1.5 
Quiescent Current Change 
ΔIq 
5mA≤Iout≤40mA 
-- 
-- 
0.1 
mA 
Output Noise Voltage 
 Vn 
10Hz≤f≤100KHz, Tj=25
o
C 
-- 
150 
-- 
µV 
Ripple Rejection Ratio 
RR 
f=120Hz, 23V≤Vin≤33V 
33 
48 
-- 
dB 
Voltage Drop 
 Vdrop 
Iout=100mA, Tj=25
o
C 
-- 
1.7 
-- 
V 
Peak Output Current 
 Io peak 
Tj=25
o
C 
-- 
0.15 
-- 
A 
Temperature Coefficient of  
Output Voltage 
ΔVout/ ΔTj 
Iout=5mA, 0
o
C≤Tj≤125
o
C 
-- 
-1.5 
-- 
mV/
o
C 
  Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as 
possible, and thermal effects must be taken into account separately. 
  This specification applies only for DC power dissipation permitted by absolute maximum ratings. 