User's Manual
Table Of Contents
- Installation and Operation Manual
- Contents
- Preface
- 1 Description
- 2 General Safety and Regulatory Information
- 3 Operation
- 4 Working with Base Stations from Your PC
- 4.1 PC Recommendations
- 4.2 Connecting Your PC to the Base Station
- 4.3 Working with the Web Interface
- 4.4 Basic Tasks
- 4.4.1 User Settings
- 4.4.2 Taking the Base Station Offline
- 4.4.3 Troubleshooting Alarms
- 4.4.4 Working with Configuration Files
- 4.4.5 Configuring Single Base Stations
- 4.4.6 Configuring Base Stations in a Channel Group
- 4.4.7 Setting Up Custom Alarms
- 4.4.8 Disabling the Front Panel Keypad
- 4.4.9 Preparing to Download Firmware
- 5 Installation
- 6 Maintenance
- 7 Troubleshooting
- 8 Replacing Modules
- Appendix A – Interface Pin Allocations
- Appendix B – Inter-Module Connections
- Appendix C – Identifying Front Panels
- Glossary
- Tait Software License Agreement
26 Description TB9400 Installation and Operation Manual
© Tait Limited December 2013 (Draft)
Table 1.1 PMU DC voltage limits
a
Parameter
Voltage Range
12V PMU 24V PMU 48V PMU
User-programmable Alarms
b
Low Battery Voltage
High Battery Voltage
10V to 14V
14V to 17.5V
20V to 28V
28V to 35V
40V to 56V
56V to 70V
User-programmable Limits
b
Startup Voltage (after shutdown)
Shutdown Voltage
10.9V to 15V ±0.3V
10V to 13.5V ±0.3V
21.8V to 30V ±0.5V
20V to 27V ±0.5V
43.6V to 60V ±1V
40V to 54V ±1V
Battery Protection (Fail-safe) Limits
Startup Voltage
Undervoltage Shutdown
Overvoltage Shutdown
Overvoltage Shutdown Reset
10.8V +0.2V
9.5V +0.3V
18.1V +
0.3V
17.1V +
0.3V
21.6V +
0.5V
19V +0.5V
36.2V +
0.5V
34.2V +
0.5V
43.2V +
1V
38V +1V
72.4V +
1V
68.4V +
1V
a. The information in this table is extracted from the Specifications Manual. Refer to the latest issue of this manual
for the most up-to-date and complete PMU specifications.
b. Using the base station’s web interface.