User's Manual
Table Of Contents
- Installation and Operation Manual Draft in Progress
- Contents
- Preface
- 1 Description
- 2 General Safety and Regulatory Information
- 3 Operation
- 4 Working with Base Stations from Your PC
- 4.1 PC Recommendations
- 4.2 Connecting Your PC to the Base Station
- 4.3 Working with the Web Interface
- 4.4 Basic Tasks
- 4.4.1 User Settings
- 4.4.2 Taking the Base Station Offline
- 4.4.3 Troubleshooting Alarms
- 4.4.4 Working with Configuration Files
- 4.4.5 Configuring Single Base Stations
- 4.4.6 Configuring Base Stations in a Channel Group
- 4.4.7 Setting Up Custom Alarms
- 4.4.8 Disabling the Front Panel Keypad
- 4.4.9 Preparing to Download Firmware
- 5 Installation
- 6 Maintenance
- 7 Troubleshooting
- 8 Replacing Modules
- Appendix A – Interface Pin Allocations
- Appendix B – Inter-Module Connections
- TaitNet P25 Glossary
- Tait Software License Agreement
DRAFT 4
TB9400 Installation and Operation Manual General Safety and Regulatory Information 29
© Tait Electronics Limited September 2011
2 General Safety and Regulatory
Information
This chapter provides general information on safety precautions for
operating the base station.
2.1 Personal Safety
2.1.1 Unpacking and Moving the Equipment
To prevent personal injury and equipment damage, we recommend that two
people unpack and move the equipment.
Caution A subrack complete with modules can weigh up to
55 lb (25 kg), or up to 62 lb (28 kg) complete with
packaging. We recommend that you have another
person help you unpack and move the equipment.
The TBAA03-16 carrying handles will make it easier
to move the equipment once it has been unpacked.
If necessary, remove the modules from the subrack
before moving it (refer to “Replacing Modules” on
page 93). In all cases follow safe lifting practices.
2.1.2 Lethal Voltages
Warning!! The PMU contains voltages that may be lethal.
Refer to the ratings label on the rear of the
module.
The equipment must be installed so that the rear of the PMU is located in
a service access area which is accessible only by qualified personnel. The
PMU must be connected to the mains supply source by qualified personnel
in accordance with local and national regulations.
Disconnect the mains IEC connector and wait for five minutes for
the internal voltages to self-discharge before dismantling. The AC
power on/off switch does not isolate the PMU from the mains. It
breaks only the phase circuit, not the neutral.
The PMU should be serviced only by qualified technicians. There are no
user-replaceable parts inside. If the PMU is damaged and does not function