User's Manual
Table Of Contents
- Installation and Operation Manual Draft in Progress
- Contents
- Preface
- 1 Description
- 2 General Safety and Regulatory Information
- 3 Operation
- 4 Working with Base Stations from Your PC
- 4.1 PC Recommendations
- 4.2 Connecting Your PC to the Base Station
- 4.3 Working with the Web Interface
- 4.4 Basic Tasks
- 4.4.1 User Settings
- 4.4.2 Taking the Base Station Offline
- 4.4.3 Troubleshooting Alarms
- 4.4.4 Working with Configuration Files
- 4.4.5 Configuring Single Base Stations
- 4.4.6 Configuring Base Stations in a Channel Group
- 4.4.7 Setting Up Custom Alarms
- 4.4.8 Disabling the Front Panel Keypad
- 4.4.9 Preparing to Download Firmware
- 5 Installation
- 6 Maintenance
- 7 Troubleshooting
- 8 Replacing Modules
- Appendix A – Interface Pin Allocations
- Appendix B – Inter-Module Connections
- TaitNet P25 Glossary
- Tait Software License Agreement
DRAFT 4
112 Appendix B – Inter-Module Connections TB9400 Installation and Operation Manual
© Tait Electronics Limited September 2011
Single 50 W Base Station
The connections between modules at the front of a single 50 W base station
are shown below.
DC Supply The PA is powered by a direct connection from the PMU. The other
modules in the subrack are powered from the PMU via the subrack
interconnect board. The DC supply to the reciter is via the system control
bus ribbon cable.
Single 50 W base station inter-module connections
b
28 VDC output for PA
g
transmit reverse input
c
not used
h
system control bus and 28 VDC input
d
system control bus
i
transmit forward output
e
transmit reverse output
j
transmit forward input
f
28 VDC input
1)
28 VDC output to subrack interconnect board
PMU
reciter
PA
b defg
hijd1)
c