User's Manual
TB9300 Installation and Operation Manual Description 11
© Tait Limited March 2017
1.1 Features
The following are some of the features of the base station:
■ Fully compliant with the DMR Tier 2 and Tier 3 Standards.
Can therefore interoperate with any similarly compliant radios.
■ Analog conventional repeater operation.
■ MPT operation as control channel or traffic channel transceiver in MPT/
IP network including standalone operation.
■ Can be completely managed remotely from a PC running a web
browser: configuration, alarm monitoring, fault diagnosis, feature and
firmware upgrades. Alarms can also be reported via SNMP traps,
allowing integration with an SNMP-based network management
system.
■ An integrated wiring solution is provided for the system control bus and
DC power connections to each module in the subrack.
■ Reciters (receiver/exciter modules) can be replaced without affecting
the operation of other reciters in the same subrack.
■ Rugged construction with generous heatsinks and fan-forced cooling
for continuous operation from –22°F to +140°F (–30°C to +60°C).