User's Manual
Table Of Contents
- Installation and Operation Manual
- Tait Contact Information
- Contents
- Preface
- 1 Introduction
- 2 Mechanical Description
- 3 Functional Description
- 4 Installation
- 5 Replacing Modules
- 5.1 Removing the Base Station and Opening the Tray
- 5.2 Replacing the UI Board
- 5.3 Replacing the Receiver Module
- 5.4 Replacing the Transmitter Module
- 5.5 Replacing the SI Board
- 5.6 Replacing the Transmitter and Receiver Fans
- 5.7 Replacing the Fan Power Board
- 5.8 Replacing the Temperature Sensor Board
- 5.9 Replacing the AC Power Supply Unit, Fan and Filter Module
- 5.10 Replacing the Speaker
- 5.11 Final Reassembly
- 6 Connections
- 7 Preparation for Operation
- 7.1 Introduction
- 7.2 Mode of Operation
- 7.3 Line-controlled Base
- 7.4 Talk Through Repeater
- 7.5 RF Modem
- 7.6 Data Repeater
- 7.7 TaitNet Trunking
- 7.8 Programmable Features
- 7.9 Additional Settings
- 7.10 Adding Subaudible Signalling
- 7.11 Soft Off (Tx Tail Time)
- 7.12 Tone On Idle (TOI)
- 7.13 Fan Operation
- 7.14 Channel ID
- 7.15 Relay Polarity
- 7.16 Channel Increment and Decrement by Function Keys
- 7.17 Carrier Wave Identification (CWID)
- 8 Maintenance Guide
- Glossary
- Tait General Software Licence Agreement
- Directive 1999/5/EC Declaration of Conformity
40 Functional Description TB7100 Installation and Operation Manual
© Tait Electronics Limited December 2005
3.5 Fan Operation
The cooling fans are mounted behind the front panel. All fans in the chassis
must be of the same type.
Dissipation of Heat Heat needs to be dissipated from a number of components within the
internal AC power supply unit, transmitter and receiver modules, including
the following:
■ 9V regulator
■ RF PA
■ driver for RF PA
■ audio PA
The mechanisms by which the heat is conducted away in each case are
described below.
Dissipation of Heat
from Transmitter
The transmitter board is mounted directly onto a heatsink through which
the forced air from the fans is ducted.
Dissipation of Heat
from Regulator and
Audio PA
Heat from the audio PA and 9V regulator on the receiver board is conducted
away by a small aluminium heatsink and mounting boss. The heatsink and
boss contact the underside of the board where the components are mounted
and thermal paste ensures a good thermal transfer between the two surfaces.
Dissipation of Heat
from RF PAs and
Driver
Heat from the RF PAs and driver is conducted to the heatsink through a
copper separator plate. The copper plate is fixed to the underside of the
board and the components soldered directly to it. The copper plate is
mounted directly to the main heatsink boss and a coating of thermal paste
ensures good thermal transfer between these two surfaces.
Dissipation of Heat
from Internal AC
Power Supply Unit
Air is forced round major components within the internal AC power supply
unit to keep them cool. Some air is passed through a small heatsink to keep
the current-carrying semiconductor devices cool.