User's Manual
Table Of Contents
- Installation and Operation Manual
- Tait Contact Information
- Contents
- Preface
- 1 Introduction
- 2 Mechanical Description
- 3 Functional Description
- 4 Installation
- 5 Replacing Modules
- 5.1 Removing the Base Station and Opening the Tray
- 5.2 Replacing the UI Board
- 5.3 Replacing the Receiver Module
- 5.4 Replacing the Transmitter Module
- 5.5 Replacing the SI Board
- 5.6 Replacing the Transmitter and Receiver Fans
- 5.7 Replacing the Fan Power Board
- 5.8 Replacing the Temperature Sensor Board
- 5.9 Replacing the AC Power Supply Unit, Fan and Filter Module
- 5.10 Replacing the Speaker
- 5.11 Final Reassembly
- 6 Connections
- 7 Preparation for Operation
- 7.1 Introduction
- 7.2 Mode of Operation
- 7.3 Line-controlled Base
- 7.4 Talk Through Repeater
- 7.5 RF Modem
- 7.6 Data Repeater
- 7.7 TaitNet Trunking
- 7.8 Programmable Features
- 7.9 Additional Settings
- 7.10 Adding Subaudible Signalling
- 7.11 Soft Off (Tx Tail Time)
- 7.12 Tone On Idle (TOI)
- 7.13 Fan Operation
- 7.14 Channel ID
- 7.15 Relay Polarity
- 7.16 Channel Increment and Decrement by Function Keys
- 7.17 Carrier Wave Identification (CWID)
- 8 Maintenance Guide
- Glossary
- Tait General Software Licence Agreement
- Directive 1999/5/EC Declaration of Conformity
14 Introduction TB7100 Installation and Operation Manual
© Tait Electronics Limited December 2005
1.5 Product Codes
This section describes the product codes used to identify products of the
TB7100 base station product line.
The product codes of the TB7100 base station product line has the format:
TBBaabb-cde-ff
where:
■ aa identifies the frequency band of the receiver:
A4=66 to 88MHz, B1=136 to 174MHz, D1=216 to 266 MHz,
H5=400 to 470MHz, H6=450 to 530MHz, H7=450 to 520MHz
■ bb identifies the frequency band of the transmitter:
A4=66 to 88MHz, B1=136 to 174MHz, D1=216 to 266 MHz,
H5=400 to 470MHz, H6=450 to 530MHz, H7=450 to 520MHz
■ c identifies the RF output power and digital architecture:
A=25W, level-1 digital architecture
B=35W to 50W, level-1 digital architecture
C=25W, level-2 digital architecture
D=35W to 50W, level-2 digital architecture
E=25W, level-3 digital architecture
F=35W to 50W, level-3 digital architecture
■ d identifies the power supply option:
0=DC only
1=internal AC power supply unit, factory preset to 115VAC
2=internal AC power supply unit, factory preset to 230VAC
■ e identifies the AC power cable:
1 = Australia/New Zealand
2 = United Kingdom
3 = Europe
4 = USA
■ ff identifies base station options:
00=no options