User's Manual
Table Of Contents
- Installation and Operation Manual
- Tait Contact Information
- Contents
- Preface
- 1 Introduction
- 2 Mechanical Description
- 3 Functional Description
- 4 Installation
- 5 Replacing Modules
- 5.1 Removing the Base Station and Opening the Tray
- 5.2 Replacing the UI Board
- 5.3 Replacing the Receiver Module
- 5.4 Replacing the Transmitter Module
- 5.5 Replacing the SI Board
- 5.6 Replacing the Transmitter and Receiver Fans
- 5.7 Replacing the Fan Power Board
- 5.8 Replacing the Temperature Sensor Board
- 5.9 Replacing the AC Power Supply Unit, Fan and Filter Module
- 5.10 Replacing the Speaker
- 5.11 Final Reassembly
- 6 Connections
- 7 Preparation for Operation
- 7.1 Introduction
- 7.2 Mode of Operation
- 7.3 Line-controlled Base
- 7.4 Talk Through Repeater
- 7.5 RF Modem
- 7.6 Data Repeater
- 7.7 TaitNet Trunking
- 7.8 Programmable Features
- 7.9 Additional Settings
- 7.10 Adding Subaudible Signalling
- 7.11 Soft Off (Tx Tail Time)
- 7.12 Tone On Idle (TOI)
- 7.13 Fan Operation
- 7.14 Channel ID
- 7.15 Relay Polarity
- 7.16 Channel Increment and Decrement by Function Keys
- 7.17 Carrier Wave Identification (CWID)
- 8 Maintenance Guide
- Glossary
- Tait General Software Licence Agreement
- Directive 1999/5/EC Declaration of Conformity
TB7100 Installation and Operation Manual Preparation for Operation 107
© Tait Electronics Limited December 2005
7.8.3 Mandatory Settings
The mandatory settings must not be changed from their default states or the
base station will not operate correctly. The mandatory settings in the
receiver module are not the same as those in the transmitter module.
The reset to defaults feature in the TB7100 programming application will
ensure all mandatory settings are correct for the selected module type.
The mandatory settings are not locked out. It is possible to change a
mandatory setting from its required state.
Receiver Mandatory
Settings
The mandatory settings for the receiver are shown below. If these change,
the receiver will no longer operate.
Form Tab Item Name Setting
Data General Output SDMs Automatically Disabled
Data Serial Communications Data_Port AUX
Data Serial Communications XON_Character 11
Data Serial Communications XOFF_Character 13
Basic Settings Basic Network Settings TX Timer Duration 1
Basic Settings Basic Network Settings TX Lockout Duration 250
Basic Settings Sub Audible Signalling CTCSS Lead Out Delay 0
Basic Settings Sub Audible Signalling Invert Tx DCS Disabled
Basic Settings Sub Audible Signalling DCS Lead Out Delay 0
Channels Detailed TX_Frequency 000.000000
Channels Detailed TX Sig none
Channels Detailed Power off
UI Preferences User Interface Confidence Tones Disabled
UI Preferences User Interface Silent Mode Disabled
UI Preferences Audible Indicators Enabled All Disabled
Startup Startup Power On Mode Power on
Startup Startup Reset On Error Enabled
PTT MIC PTT PTT Priority high
PTT MIC PTT Audio Source CH MIC
PTT External PTT 1 PTT Transmission Type none
PTT External PTT 1 PTT Priority medium
PTT External PTT 1 Audio Source CH MIC