User's Manual

32 Operating Controls TB8100 Installation and Operation Manual
© Tait Electronics Limited March 2005
Alarm LED
The red alarm LED will flash at a rate of 2 to 5Hz when an alarm has been
generated by any of the TB8100 BSS modules. It will continue to flash until
the alarm is cancelled or the fault is fixed. Note that only those alarms which
are enabled using the Service Kit (Configure > Alarms > Alarm Control)
will cause this LED to flash. Refer to the Service Kit documentation for
more information.
Base Station 1
Select Button
Pressing this button selects base station 1. Pressing the button again while
base station 1 is selected has no effect. When the BSS is powered up, the
control panel selects base station 1.
Power LED The green power LED is lit when the PMU is turned on and supplying
power to the BSS.
Base Station 2
Select Button
Pressing this button selects base station 2. Pressing the button again while
base station 2 is selected has no effect.
3.1.3 Power Save Control Panel
The indicator LEDs on the power save control panel are identified in
Figure 3.3 below.
Figure 3.3 LED indicators on the power save control panel
b
power LED
c
alarm LED
c
b