Method 2
1. Connect one end of the Power Saving control cable b to the Power
Saving control connector
c at the rear of the PA.
2. Cut the socket off the other end of the cable. Connect the wires
directly to the D-range plug fitted to the system interface connector
e as follows:
red - digital out 1
black - ground.
The pin allocations for the Power Saving control connector on the PA are
given in the following table.
If you wish to make up your own cable, use the following connector for
both the PA and reciter connections:
2x1-way Molex 43025-0200/crimp socket 43030-0001 female.
Figure 7.13 Fitting the Power Saving control cable to a 12V PA
becd
reciter shown with TaitNet RS-232
system interface board
Pin Signal Name Signal Type Notes
1 PA shutdown input active low
2 ground ground
external view