User's Manual
TB8100 Installation and Operation Manual Connection 111
© Tait Electronics Limited March 2005
Note that the PMU connector used in the TBA2241 and TBA2242 cables
was changed in August 2004 to match the change of connector in the PMU.
The old cables are still available under Tait part numbers 219-02895-00
(single) and 219-02896-00 (double). Contact your nearest Tait Dealer or
Customer Service Organisation for details on the full range of wiring kits
available.
7.3 RF Connections
RF Input and Output The RF input to the TB8100 BSS is via the lower BNC/TNC connector
on the rear panel of the reciter. The RF output is via the N-type connector
on the rear panel of the PA (refer to Figure 7.4 on page 103).
We recommend that you use dual-screened coaxial cable such as RG223 for
the BNC/TNC connections, and RG214 for the N-type connections.
When the base station is used in simplex mode using a single antenna with
a coaxial changeover relay, the isolation of this relay must be t40 dB.