42 Power Management Unit Specifications TB8100 Specifications Manual
© Tait Electronics Limited October 2004
General
Efficiency at Rated Output*
Input-to-chassis Isolation
Input-to-output Isolation
Output-to-chassis Isolation
*at 220VAC
86%
1500VAC, 50Hz, 1 minute
3000VAC, 50Hz, 1 minute
500VAC, 50Hz, 1 minute
Input - AC Module (Continued)
Input - DC Module
Input
Factory-set Limits
Minimum Run Voltage
Minimum Turn-on Voltage
Maximum Run Voltage
Maximum Turn-on Voltage
User-programmable Limits*
+
Low Battery Shutdown Voltage
Low Battery Restart Voltage
(after shutdown)
User-programmable Alarms*
Low Battery Voltage
High Battery Voltage
*using the Service Kit software
+
only available if the standby power supply card is fitted
12V
9.5V ±0.3V
11.7V ±0.3V
18.1V ±0.3V
17.1V ±0.3V
10V to 13.5V
11.5V to 15.0V
10V to 14V
14V to 17.5V
24V
19V ±0.5V
23.4V ±0.5V
36.2V ±0.5V
34.2V ±0.5V
20V to 27V
23V to 30V
20V to 28V
28V to 35V
48V
38V ±1V
46.8V ±1V
72.4V ±1V
68.4V ±1V
40V to 54V
46V to 60V
40V to 56V
56V to 70V
Protection
Fault Current (Input)
Wrong Input Voltage
Wrong Input Voltage Polarity
circuit breaker or fuse in external wiring*
electronic lock-out
shunt diode
*provided by user
General
Efficiency at Rated Output
12VDC
24VDC
48VDC
Input-to-output Isolation
82%
85%
90%
1000VAC, 50Hz, 1 minute