User's Manual

12 Disconnecting from the Base Station/Reciter MB8100-90-00-806 © TEL 2004
Connecting to the Reciter/PA in the Subrack
For the PA calibration procedures and the reciter calibration procedures that do
not require access to the tuning holes, you can leave the modules in the subrack
and connect your PC to the base station as follows.
Equipment An IBM compatible PC
RS-232 cable
Setup
To connect to the base station
1. Connect your computer to the base station by plugging the RS-232 cable
into the serial port of the base station’s control panel.
2. Start the TB8100 Calibration Kit program, and check that the correct COM
port is selected.
3. Click Connect to start the connection process.
4. As soon as you see the “Waiting for logon prompt from Reciter” screen,
power up the base station.
5. When the TB8100 Calibration Kit program has successfully connected to
the base station, the Calibration Wizards are displayed in the main window.
You are now ready to calibrate the reciter or PA.
Disconnecting from the Base Station/Reciter
To disconnect from the base station or reciter before closing the program, select
File > Exit, or click Disconnect.
Important: Before disconnecting from the base station, ensure that
you have completed any calibration process that you have started. If
a calibration process is not completed, the base station could be left
in an uncalibrated state.
4
1
3
2
1 Base station 3 RS-232 cable
2 Serial port 4 PC