User's Manual

TB8100 Calibration Kit User’s Manual Configuring TB8100 Calibration Kit 9
2. Tune each of the resonators in the first set once to give the best response.
3. Insert the tuning tool into the first hole of the second set. You can start with
the top hole and proceed down to the bottom hole, or vice versa (again,
never start with the centre hole).
4. Tune each of the resonators in the second set once to give the best response.
5. Repeat this procedure as necessary to refine the response.
Configuring TB8100 Calibration Kit
Note: For information on computer system requirements, and
installing the TB8100 Calibration Kit, see the TB8100 Installation
and Operation Manual.
Selecting the Communications Port
Before you connect to a base station, you should first define the
communications (COM) port that you want to use.
To select the COM port
1. Select Tools > Options.
2. Select the port that you want to use from the COM Port list.
Note: The available COM ports are detected by the program and
appear in the list.
3. Click OK.
The COM port you selected is now shown on the status bar.
First set
Second set