User's Manual Part 5

 

  
* (,
&
All sub-assemblies within the T2008 power supply (e.g. transformer, PCB/heatsink) are
housed in a specially moulded plastic case with no screws. The top and bottom halves
of the plastic case are fastened by four self-tapping screws.
All electrical components except the transformer and LED are mounted on either the
larger regulator/heatsink PCB or on the smaller mains input PCB.Disassembly
 Disconnect the unit from the mains supply before attempting to remove
the top case.
!"#$%&
The power supply contains voltages that may be lethal. The unit should not be disman-
tled without first disconnecting the mains supply. Servicing should be carried out only
by qualified technicians.
!"%
If the power supply is operated at high output currents and/or a high duty cycle rate
for a prolonged period of time (e.g. more than 10 minutes), the heatsink will become
very hot. Do not touch.
Do not operate the power supply in a sealed cabinet. Ensure that there is an adequate
airflow past the unit and in particular past the heatsink at the back of the unit.
!"'!(
If the mains supply cord needs replacing, it must be replaced with a mains supply cord
of the same size and type as originally fitted.
),$!
Turn the unit upside down and remove the two self-tapping screws.
Turn the unit back on its feet and remove the two top screws.
Carefully lift the top case away from the unit.
All the sub-assemblies are now easily accessible, and can be lifted out as neces-
sary.