To pair an air unit and an ground unit:
1. Both air unit and ground unit are powered on.
2. Connect the air and ground unit.
3. Press the physical bind button of the air unit, last 3-5s. The LED light next to the bind
button flashes green, indicating that it is in the binding state.
4. Press the physical bind button of the ground unit, last 3-5s. The LED light next to the
bind button flashes green, indicating that it is in the binding state.
Note:
(1) If modules binding with different firmware version, the binding operation may fail.
(2) If the program of the air unit or the ground unit is burned incorrectly, such as burning
the air unit to the ground unit, and performing the binding operation between the wrong
air unit and the ground unit, the binding operation will fail.
6.6.Telemetry & RC
Telemetry
UART singal: LVCMOS-3.3V.
Pin-out: G DR DT G RX TX.
Debug-DR/DT, Telemetry-RX/TX.
RC
PPM/S.BUS singal: LVCMOS-3.3V.
Pin-out: II G V+ G L H.
II: PPM/SBUS G: GND V+: POWER(5V) G: GND L: CAN-bus-L
H: CAN-bus-H (CAN-bus is not supported yet).
The RC port can provide 5V power supply for S. BUS application.