Safety Statements
To avoid contact with electrical current:
- Never install electrical wiring during an electrical storm
- Never install an Ethernet connection in wet locations unless that connector is
specifically designed for wet locations
- Use caution when installing or modifying Ethernet lines
- Do not place Ethernet wiring or connections in any conduit, outlet or junction
box containing electrical wiring
- Installation of inside wire may bring you close to electrical wire, conduit,
terminals and other electrical facilities. Extreme caution must be used to avoid
electrical shock from such facilities. You must avoid contact with all such
facilities
- Ethernet wiring must be at least 6 feet from bare power wiring or lightning rods
and associated wires, and at least 6 inches from other wire (antenna wires,
doorbell wires, wires from transformers to neon signs), steam or hot water
pipes, and heating ducts
- Do not place an Ethernet connection where it would allow a person to use an
Ethernet device while in a bathtub, shower, swimming pool, or similar
hazardous location
- Protectors and grounding wire placed by the service provider must not be
connected to, removed, or modified by the customer
- Do not touch uninsulated Ethernet wiring if lightning is likely!
Any external communications wiring you may install needs to be constructed to all
relevant electrical codes. In the United States this is the National Electrical Code Article
800. Contact a licensed electrician for details.
4.2.2 Default Reader Network Settings
You will not be able to configure any network setting before no Ethernet link has been detected.
It depends to you to engage the reader with your Ethernet network correctly first.
Additionally, the default settings for the reader network configuration are:
- DHCP : Off
- Static IP Address : 192.168.0.2
- Subnet Mask : 255.255.255.0
- Default Gateway : 0.0.0.0