User Manual

Table Of Contents
Performance Test
L-SP2 EAS Performance Test
Library / Facility installed: ______________________________
Location of Pedestals: ______________________________
Specific installation notes: ______________________________
Figure 36: Test Chart
umber of T s us
Reader
0 100 200 300 700 800 850
1320 mm.
920 mm.
520 mm.
Floor Level
Pedestal B
S/N:
Software Version:
Zone 1
Zone 6
Zone 11 Zone 15
Zone 5
Zone 10
183mm. 366 mm. 549 mm. 732 mm.
Pedestal A
S/N:
Software Version:
Aera with no item detection
600500400
N ag ed:
m lig work OK ) Alar hts ing (Y/N
ence Tag(s): Serial number(s) of refer Buzzers functioning OK (Y/N)
Test Result %
est comments:
T
Tested By: Name:
Company:
Signature:
Date
December 2004 Revision 1.0 47/50