9) Activating the LORIKEET ENCODER Device
At the time of installation connect the LORIKEET ENCODER to a Sensus protocol enabled
Encoder/Meter and trigger the device Radio Test Mode as previously described via a Swipe or
NFC Tap. Triggering Radio Test Mode while a compatible Sensus protocol Encoder/Meter is
attached sets the device into Operational Mode for the serviceable life of the LORIKEET
ENCODE.
NOTE - If a LORIKEET ENCODER is disconnected from a Sensus protocol sensor at any
point, the LORIKEET does not return to Flight Mode, instead reporting communication
errors.
10) Confirming an Installation
Reading a LORIKEET ENCODER endpoint immediately after installation verifies proper
operation and reading performance. Before leaving the installation site, the installer can use a
web-app to confirm the endpoint wiring is correct and that the endpoint is broadcasting end-
to-end data from the Encoder/Meter to the Taggle data platform. Access to this page will be
granted by Taggle Systems to authorised persons.
11) Configuration via NFC
NFC interactions that modify the behavior of the device require an approved Taggle NFC
application. All communications are encrypted using AES-128 with a unique key per device.
Contact Taggle for further information.