User's Manual

9
3.) Set the TAPE SELECTOR SWITCH found on the left side of the recorder to match with the
type of cassette being used. This selects the proper bias and internal recorder equalization to suit
the most common types of cassette tapes.
NORM normal ferric oxide tapes
CrO2 chromium dioxide and other tapes requiring 70ms EQ and high bias
METAL metal tapes.
4.) Set the RECORD LEVEL MODE SELECT SWITCH on the front panel of the recorder to
the "ALC" position.
5.) Set the TAPE SPEED SELECT SWITCH on the front panel of the recorder to either the
"LOW" or "STANDARD" position. "STANDARD" position will set tape speed to 1 7/8 IPS and
will give you 45 minutes of recording time per side from a C-90 cassette tape. The "LOW"
position slows down the tape speed to 15/16 IPS and will provide 90 minutes of recording time per
side from a C-90 tape.
NOTE: QUALITY OF THE RECORDING MAY DETERIORATE BY USING THE "LOW" TAPE
SPEED POSITION.
NOTE: DO NOT CHANGE THE SPEED SELECT SWITCH DURING RECORDING!
6.) The switch settings on the right side of the Marantz Recorder should be set as follows:
a.) INPUT SOURCE : Line
b.) AUTO NOISE CANCELLING - ANC: Normal
c.) INTERNAL MIC ATTENUATION: Any position
7.) If a Marantz 221 is installed in your Citation, the MONITOR SWITCH found on the front of
the Marantz may be placed in the SOURCE position to monitor the receiver before it is recorded,
or the TAPE position to monitor the signal actually recorded on the tape. When the Monitor
switch is set to SOURCE, howling may occur. At that time, lower the monitoring volume.
8.) On the Marantz 221, with the MEMORY REWIND SWITCH set to the ON position, the tape
travel stops when the TAPE COUNTER reaches "999". Reset the tape counter via the button
found next to the counter.
9.) Press the RECORD and PLAY buttons on the cassette deck simultaneously.
10.) Your Citation will now record all transmissions from your transmitter.
11.) No record level adjustment is required as long as the REC MODE control on the front panel
of the recorder is set to the "ALC" position. Manual operation of the record level is possible by
selecting either the "LIMITER" or the "MANUAL" positions.
MANUAL RECORDING LEVEL OPERATION: This mode of operation will
permit manual control of the recording level for maximum dynamic range. Set the
REC MODE control to the "MANUAL" position. During operation, adjust the
MANUAL RECORD LEVEL CONTROL KNOB while watching the VU METER
found on the front panel of the recorder. Ordinarily, the VU meter needle deflection