User Manual

PL3
PIN
NAME FUNCTION REMARKS
1 Transmit Enable < 0.5V = Transmit ON
(internal 20kS pullup)
2 DI Data Input Digital: DC coupled TTL compatible
3 AI Analog Input Analog : 750 mV p-p nominal
4 RSSI Received Signal
Strength Indication
RSSI: 0.5 - 2.0 V, 60dB dynamic range
(<33kS output impedance)
5 Squelch Open drain to <0.4V with 10kS load.
Low = No Signal
6 AF Audio Output 250mV p-p nominal
(~1kS output impedance)
Note inversion of audio from TX input to RX
output
7 DATA
O/P
Data output Open collector digital output
Note inversion of data from TX input to RX
output
8 +VOUT + 5 volt supply output VOUT= 50mA maximum current drain
9 0V 0 volts common ground
10 RS232
I/P
serial
programming
i/p
RS232 programming input
Note inverted TTL level data can also be used.
If not used, leave not connected, or connect to
ground.
11 RB1
parallel frequency
select
internal pull-up to +5V, active low12 RB2
13 RB3
Table 3 PL3 Pin Connections