Manual

P33document version 1.0 | © 2022 tacterion GmbH | all rights reserved
Format
ASCII characters comma separated
HFC off: res1,res2,res3,res4,res5,res6,position0,force0
HFC on: hfc1,hfc2,hfc3,hfc4,hfc5,hfc6,position0,force0
With: resX = resisitive value sensor channel X
hfcX = hybrid value sensor channel X
postion0 = position value for slider sensor
channel 0
force0 = force for slider sensor channel 0
Conn. speed:
115200baud
Sampling rate
~30Hz
Range
Range Resistive Value: 0…4095
Range Hybrid Value: dynamic
Startup delay 143ms (release RESET, time until first UART transmission)
1. For logging your data stream, click on the “File” menu and select “Log…” to save
the data in a text file on your PC. This text file will be constantly updated with the
data streamed from the electronics