b. Signal Drift
The resistive as well as the hybrid readout signals have been recorded for 10 hours of actuation
with a constant load of 4 N. The results are shown in the following plot, where the 1 second mark
is indicated by a vertical dashed line.
The values of both readout signals are furhter depicted as histograms with identical bin sizes.
Only samples recored 1 second after the actuation is initiated are included in the plot.