Datasheet

4
Document Version: 4.1 tacterion GmbH | Nymphenburger Straße 5 | 80335 Munich | Germany
Date: October 2021 Tel: +49 (0) 89 452 457 50 | support@tacterion.com | www.tacterion.com
4. Sensor Performance
a. Signal Readout-Force
The sensor signal is determined for stepwise increasing/decreasing force levels ranging from 0 N
to 10 N with 0.5 N force steps according to the depicted actuation profile.
The sensor response is measured through the EBS-10010 electronics and the readout values
obtained are plotted against the force exhibited at each step. For this purpose, an average of the
readout values recorded within each force step is determined.