Submittal Sheet

101-053
Single Zone Switching Relay
Effective: December 15, 2006 Supersedes: July 15, 2005
Submittal Data Information
Job: Engineer:
Contractor:
Rep:
ITEM NO. MODEL NO.
Printed in USA
Copyright 2006
TACO, Inc.
Submittal Data Information
Single Zone Switching Relay
Submittal Data # 101-053 Effective: 12/15/06
Supersedes: 07/15/05
Features
External Indicator Lights
Universal Replaceability
Snap-in PC Board
Simplified Wiring
Fully Enclosed Snap-Out Relays
Fuse Protected (with spare)
100% Factory Tested
Contractor Friendly PC Board Layout
Universal Thermostat Compatibility
UL and CSA Approved
Extended 3 Year Warranty
Made in the USA
Additional EXP Features
One Add-on Power Control Plug
Premium Sealed Relays
Interface with all -EXP Multi-Zone Controls
Additional SR501-845RP Features
6 Pack of Replacement Boards
Fast and Economical Field Replacement
Snaps into Existing Metal Enclosure
Replaces Honeywell RA89A, RA832A,
R845A or Comparable Relay (see chart)
The Taco Connection
Combine the reliability of the Taco
Zone Valves, Priority Zoning Circulators,
Thermostats, and the “00
®
” family of
circulators with the advanced features
of the Taco Zone Controls to achieve
total system integration. No matter
the application, Taco now provides
the products to maximize system
performance while simplifying both
installation and service.
External Diagnostics
It’s no longer necessary to open the box
to troubleshoot the system. Externally
visible lights show full functionality of the
switching relay. The green light should
always be on, indicating that power is
connected. When the thermostat calls
for heat, both the appropriate circulator
and red indicating light is energized.
Switching Relays
The single zone switching relay should be standard equipment for every installer. No matter
what type of job, our single zone switching relay replaces every brand made by every manufac-
turer, and will even fit into the existing metal enclosure without rewiring incoming connections.
The single zone switching relay is UL and CSA listed, uses a standard “ice cube” replaceable relay
and is compatible with conventional and programmable thermostats. External indicator lights
provide instant diagnostic feedback, making a snap of service calls or new installation start-ups.
Special SR501-845RP contractor multi-packs also available.
Taco Expandable Switching Relays
Whether you want to expand up to 20 zones or utilize the advanced features of the Add-on
Power Controls, Taco -EXP controls allow for a simple integration of advanced features. Energy
savings and increased comfort can be easily achieved in any new or existing system by plugging a
PC700 Outdoor Reset Power Control into the SR501-EXP.
Wiring Diagram for Typical Installation
Switching Relays
Product Number Power Transformer Maximum Dimensions of Enclosure
Number of Zones Control Plugs Voltage Combined Load Width Height Depth
SR501 1 Zone --- 120 VAC Input 5 amps 4 1/4” 5 1/4” 2 3/4”
SR501-EXP 1 Zone 1 120 VAC Input 5 amps 4 1/4” 5 1/4” 2 3/4”
SR501-845RP 1 Zone --- 120 VAC Input 5 amps 4 1/4” 5 1/4” 2 3/4”
All Switching Relays are relay type DPDT, have a thermostat current of .18, and have a single phase motor rating per zone of
1/3 hp (5 A) @ 120 VAC. All relay contacts are rated for 0-240 Volts.
Taco SR501 Replacement Cross-Reference
Manufacturer Model Connections
Taco SR501 H N 3 4 N/O 4 N/C 5 6 N/O 6 N/C R/T W/T COM
SR501-EXP H N N Circ. Output Priority Out X X R/T W/T COM
SR501-845RP L1 L2 3 4 5 6 R/T W/T
Argo AR821 1 2 3 4 5 6 T T
AR822 L1 L2 3 4 NO 4 NC 5 6 NO 6 NC R/T G/T C
Columbus MR10 L1 L2 3 4 NO 4 NC 5 6 NO 6 NC R/T G/T C
Erie SR100 L1 N 3 4 NO 4 NC 5 6 NO 6 NC R/T G/T C
Honeywell RA89A 1 2 3 4 T T
RA832A 1 2 3 4 X X T T
R845A 1 2 3 4 5 6 T T
White-Rogers 889-189 1 2 3 4 T T
829-845 1 2 3 4 5 6 T T
Taco Inc., 1160 Cranston Street, Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360
Taco (Canada) Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 / (905) 564-9422 / Fax (905) 564-9436
www.taco-hvac.com
H
yd ronic
c
om po ne nt s
& s
yst em s
Do it Once. Do it Right.
®
TACO INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 Fax: 942-2360
TACO (Canada), Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 Telephone: (905) 564-9422 Fax: (905) 564-9436
Visit our website at: www.taco-hvac.com

Summary of content (1 pages)