Submittal Sheet

101-210
TacoSetter Bypass
Balancing Valve
Effective: February 27, 2019 Supersedes: New
Submittal Data Information
Job: Engineer:
Contractor:
Rep:
ITEM NO. MODEL NO.
LIMITED WARRANTY STATEMENT
Taco, Inc. will repair or replace without charge (at
the companys option) any Taco High Efficiency
circulator or circulator part which is proven defec-
tive under normal use within three (3) years from
the date of manufacture.
In order to obtain service under this warranty, it
is the responsibility of the purchaser to promptly
notify the local Taco stocking distributor or Taco
in writing and promptly deliver the subject product
or part, delivery prepaid, to the stocking distribu-
tor. For assistance on warranty returns, the pur-
chaser may either contact the local Taco stock-
ing distributor or Taco. If the subject product or
part contains no defect as covered in this war-
ranty, the purchaser will be billed for parts and
labor charges in effect at time of factory exami-
nation and repair.
Any Taco product or part not installed or operated
in conformity with Taco instructions or which has
been subject to misuse, misapplication, the addi-
tion of petroleum-based fluids or certain chemi-
cal additives to the systems, or other abuse, will
not be covered by this warranty.
If in doubt as to whether a particular substance
is suitable for use with a Taco product or part, or
for any application restrictions, consult the
applicable Taco instruction sheets or contact
Taco at (401-942-8000).
Taco reserves the right to provide replacement
products and parts which are substantially similar
in design and functionally equivalent to the
defective product or part. Taco reserves the right
to make changes in details of design, construc-
tion, or arrangement of materials of its products
without notification.
TACO OFFERS THIS WARRANTY IN LIEU OF
ALL OTHER EXPRESS WARRANTIES. ANY
WARRANTY IMPLIED BY LAW INCLUDING
WARRANTIES OF MERCHANTABILITY OR
FITNESS IS IN EFFECT ONLY FOR THE DURA-
TION OF THE EXPRESS WARRANTY SET
FORTH IN THE FIRST PARAGRAPH ABOVE.
THE ABOVE WARRANTIES ARE IN LIEU OF
ALL OTHER WARRANTIES, EXPRESS OR
STATUTORY, OR ANY OTHER WARRANTY
OBLIGATION ON THE PART OF TACO.
TACO WILL NOT BE LIABLE FOR ANY SPE-
CIAL, INCIDENTAL, INDIRECT OR CONSE-
QUENTIAL DAMAGES RESULTING FROM THE
USE OF ITS PRODUCTS OR ANY INCIDENTAL
COSTS OF REMOVING OR REPLACING
DEFECTIVE PRODUCTS.
This warranty gives the purchaser specific rights,
and the purchaser may have other rights which
vary from state to state. Some states do not
allow limitations on how long an implied warranty
lasts or on the exclusion of incidental or conse-
quential damages, so these limitations or exclu-
sions may not apply to you.
2019
Specifications
Direct reading in gallons per minute (GPM)
• Convenient flow reading memory stop
Fast & easy installation
Quick & simple flow rate adjustment
Unique bybass design
Install in almost any location & orientation
Low pressure drop
Customizable Union Fitting Sets sold separately
Materials of Construction
Housing: .............................Brass
Sight Glass: .......................Heat & impact
..................................................resistant plastic
Seals: ......................................EPDM
Performance Data
Max. Operating Temp: 212˚F (100˚C)
Max. Operation Pressure: 145psi (10 bar)
Measuring Accuracy: +10% of indicated value
Not suitable for potable water
Use with water or 50% water/glycol solution
Measuring Accuracy
- Measurment range 20-80%
+5% of indicated value
- Measurment range 20-80%
+10% of indicated value
Pressure Loss Diagrams
(Actual pressure loss may vary slightly depending on union tting type)
DIMENSIONAL DRAWING
Application
TacoSetter Bypass balancing valves oer an easy and accurate method of adjusting
the ow rates for closed loop hydronic heating and cooling systems.
Model Performance & Spec Chart
1" Fitting Sets
(Sold Seperately)
1 ¼” Fitting Set
(For Model 7206-3 Sold Separately)
Description Part Number
½” Union Sweat
UFS-050S
½” Union FNPT
UFS-050T
½” Union Press
UFS-050P
¾” Union Sweat
UFS-075S
¾” Union FNPT
UFS-075T
¾” Union Press
UFS-075P
1” Union Sweat
UFS-100S
1” Union Press
UFS-100P
Description Part Number
1” Union MNPT
UFS125-100T
Model
Number
Connection
Size
Flow Range
(GPM)
Max Flow
(GPM)
Temperature
Range (F)
Max Pressure
(PSI)
7204-3 1” Union 1 - 4 4
32˚ - 212˚ 1457205-3 1” Union 2 - 8 8
7206-3 1-1/4” Union 3 -10 10
Model
Number
A B C Ship Wt.
in. mm in. mm in. mm lbs. Kg
7204-3
5.1 129 1 25 1.8 46 2.00 0.9
7205-3
5.1 129 1 25 1.8 46 2.00 0.9
7206-3
6 152 1.25 32 2.3 58 2.25 1
35
3.5
.35
35
3.5
.35
35
3.5
.35
0
0 251
4
0
0 2.5 8 25
0
0 102.5 25
B
B
B
C
C
C
D
D
D
223.2360.000 (DN 20 | ¾" | 4...15 l/min)
223.2370.000 (DN 20 | 1" | 4...15 l/min)
223.2461.000 (DN 25 | 1" | 10...40 l/min)
223.2471.000 (DN 25 | 1¼" | 10...40 l/min)
223.2362.000 (DN 20 | ¾" | 8...30 l/min)
223.2372.000
7204-3 7205-3 7206-3
(DN 20 | 1" | 8...30 l/min)
Pressure loss (Ft. H
2
O)
Pressure loss (Ft. H
2
O)
Pressure loss (Ft. H
2
O)
Flow rate (gpm)
Flow rate (gpm)
Flow rate (gpm)
A C