Product Brochure

Submittal Data Information
Model 00R-IFC
®
Radiant Heating Circulator
Submittal Data # 101-096
Supersedes: 07/01/09
Effective: 03/25/13
Performance Field - 60Hz
Pump Dimensions & Weights
Mounting Positions
*Flange Orientation Type
Features
Specifically designed for
radiant heating applications
Integral Flow Check (IFC
®
)
Simplifies piping
Prevents gravity flow / reverse flow
Eliminates separate in-line flow check
Reduces installed cost
Improves performance
Easy to service
LED indicator light (Cast Iron Model Only)
Unique replaceable cartridge-field
serviceable
Unmatched reliability-maintenance free
Quiet, efficient operation
Self lubricating, no mechanical seal
Cast iron or Stainless Steel construction,
flanged connections
Materials of Construction
Casing (Volute): Cast Iron or Stainless Steel
Integral Flow Check (IFC
®
):
Body, Plunger..........Acetal
O-ring Seals ..............EPDM
Spring ........................... Stainless Steel
Stator Housing: .................... Steel
Cartridge: ................................. Stainless Steel
Impeller: .................................... Non-Metallic
Shaft: ........................................... Ceramic
Bearings: ................................... Carbon
O-Ring & Gaskets: .............. EPDM
Model Nomenclature
F – Cast Iron, Flanged
SF – Stainless Steel, Flanged
IFC – Integral Flow Check
Performance Data
Flow Range: 0 - 12.5 GPM
Head Range: 0 - 15 Feet
Min. Fluid Temperature: 40˚F (4˚C)
Max. Fluid Temperature: 230°F (110˚C)
Max. Working Pressure: 125 psi
Connection Sizes:
3/4”, 1”, 1-1/4”, 1-1/2” Flanged
Taco Inc., 1160 Cranston Street. Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360
Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436
www.taco-hvac.com
Electrical Data
Application
The 00R-IFC Radiant Heating Circulator with Integral Flow Check specifically fits
the higher head and lower flow designs used in many Radiant Heating systems.
The circulator's performance curve delivers flow that can be used in a wide com-
bination of tube diameters and length of runs. The removable, spring loaded
Integral Flow Check (IFC
®
) prevents gravity flow/reverse flow. By locating the IFC
inside the pump casing, a separate in-line flow check is eliminated, simplifying pip-
ing and reducing installation costs. It also makes for a modern, clean looking job
when mounting the pump in vertical runs of pipe, pumping away from the boiler.
Both the IFC and cartridge are easily accessed for service instead of replacing the
entire unit. Available in Cast Iron and Stainless Steel construction.
Standard
Optional
Standard (S)
Rotated (R)
OK if over 20 psi
Models Casing
Flange
Type*
A B C D E F
Ship Wt.
in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
00R-F6-I IFC Cast Iron R
5-15/16
151 4-1/2 114
3-3/16
81
2-15/16
75 5 127 6-3/8 162 9.0 4.0
00R-SF6-I IFC St. Steel R
5-15/16
151 4-1/2 114
3-3/16
81
2-15/16
75 5 127 6-3/8 162 8.0 36.
00R-SF6 IFC St. Steel S
6
152 4 102
3-3/16
81
2-15/16
75 5 127 6-3/8 162 8.0 3.6
Model
Volts Hz Ph Amps RPM
HP
Cast Iron
115
60 1 .71 3250 1/25
Stainless Steel
115
60 1 .75 3250 1/25
Motor
Type
Permanent Split Capacitor
Impedance Protected
Low-Lead Compliant
Certifications & Listings
FOR INDOOR USE ONLY