4. Wiring the circulator: Disconnect AC power supply. Remove terminal
box cover. Attach a wiring connector into knockout hole. Use flexible
conduit only. Connect Line/Hot power to the black lead, Neutral to the
white lead. See wiring diagram.
N
ote: If pigtail leads provided are not used, be sure to trim field wire to a
strip length of .25" (+/- .025") to prevent exposed wire causing a short at the
t
erminal plug. Connect line and neutral to green terminal plug as shown in
diagram. Depress the spring tab with a small screwdriver to insert wire into
p
lug. Release tabs to complete connection. The 007e is a double insulated
circulator, no grounding wire is necessary. Replace terminal box cover.
5. Start the circulator: When purging the system, it is recommended to
run the circulator long enough to remove all remaining air from the bear-
ing chamber. This is especially important when installing the circulator in
the off-season. An orange LED will illuminate when the 007e is powered
on.
CAUTION: Never run the circulator dry or permanent damage may result.
ATTENTION: Ne laissez jamais le circulateur tourner à sec, des dommages permanents peuvent en résulter.
NEUTRAL
TERMINAL BOX
LN
No ground wire is required.
G
reen Terminal Plug
Spring Tabs
WIRE NUT
WHITE
BLACK
LINE
CAUTION: Do not attempt to remove LED panel from circulator. Serious damage to circulator electronics may
result.
ATTENTION: N'essayez pas de retirer le panneau de LED du circulateur. Des dommages s
érieux à l'électron-
ique du circulateur peuvent en résulter.
007e™ Performance Curve