Submittal Sheet

50
0
5
10
15
20
25
30
35
10 15 20 25 30 35 40 45 50
Flow Rate Q [GPM]
Head
[ft.]
C2 = 12 ft.
C1 = 6 ft.
C5 = 30ft.
C4 = 24ft.
C3 = 18ft.
0034ePlus
High-Eciency Circulator
Constant Pressure Curves
50
0
20
60
80
40
100
120
140
160
180
10 15 20 25 30 35 40 45 50
Flow Rate Q [GPM]
Power [W]
C5
C3
C4
C2
C1
0034ePlus
High-Eciency Circulator
Constant Pressure Curves
Power Consumption
50 10 15 20 25 30 35 40 45 50 55
Flow Rate Q [GPM]
0
5
10
15
20
25
30
35
Head [ft.]
0034ePlus
High-Eciency Circulator
activeADAPT Range
activeADAPT
50 10 15 20 25 30 35 40 45 50 55
Flow Rate Q [GPM]
0
30
60
90
120
150
180
Power [W]
0034ePlus
High-Eciency Circulator
activeADAPT Range
Power Consumption
activeADAPT
activeADAPT™ Mode:
activeADAPT is an operating mode
designed for constant circulation
systems. On this setting, the circulator
will sense changes in system ow
and head conditions and adjust the
operating curve automatically.
Purple LED
activeADAPT
Constant Pressure Mode:
Circulator will vary speed to maintain desired feet
of head constant pressure curve. There are 5 setting
options: 6 - 30 feet.
Orange LED
C