Instructions / Assembly
2
Installing the Hot-LinkPlus-e Hot-Link Valve:
1.
Select  the  hot  water  faucet  furthest  from  the  water  heater.  If
your  plumbing  system  branches  in  two 
different  directions,
another Hot-Link Valve may need to be installed at the end of
each run (see Figure 1 on page 1).
3. Open the hot and cold faucets to purge water from the lines.
4. Disconnect  the  hot  and  cold  flex  hoses  from  the  1/2"  faucet
connections  beneath  the  sink  and  reconnect  them  to  the
respective  hot  and  cold  inlet  ports  on  the  Hot-Link  Valve.
Locate the  flow arrows  on the side of the valve to  verify flow
direction.
5. Install the 1/2" x 1/2" flex hoses provided. Connect one hose to
the hot outlet of the valve and the hot water connection on the
faucet  (left  side).  Connect  the  second  flex  hose  to  the  cold
outlet of the valve and the cold water connection on the faucet
(right side). See Figure 5 below.
6. When all connections are made, open angle stop valves and
check for leaks.
7. Attach the Hot-Link Valve to the wall using anchor
screws provided.
NOTE: The  Hot-Link Valve can  be disassembled for  service and 
cleaning. Repeat steps number 2 and  3. Unthread the valve stem 
from the body and clean internal screen of debris (see Figures 3 & 
4  above).  Reattach  valve  stem  securely  to  prevent  leaks.  Open 
angle stop valves and check for leaks.
Hot
Shut-O
Valve
Shut-O
Valve
1/2” Male
(2) New 1/2”x1/2”
Taco® supplied ex lines
(female x female)
Use (2) existing female
x female ex lines
1/2” Male
Hot-Link® includes (2)
plastic wall anchors
& screws
Cold
1/2” 
3/8” Male 
3/8” Male 
1/2” 
HOT COLD
CAUTION: Do not use pipe dope or Teflon tape  on the 
valve body threads.
CAUTION: Use caution when attaching flex hoses to the Hot-Link 
Valve to prevent cross-threading or stripping of the threads.
Hot-Link Valve Hot-Link Valve removable cartridge for service
Application:
Taco's  Hot-LinkPlus-e  SmartPlug  Instant  Hot  Water  Control  is 
designed  to  upgrade  any  hot  water  recirculation  system. 
SmartPlug replaces inefficient timers and aquastats typically used 
in  recirculation  systems.  It  adds  intelligence  to  your  system  by 
learning when hot water is used  in the home. The pipe-mounted 
sensor records  daily hot  water usage  patterns during  the course 
of  the  week.  Recorded  data  is  used  to  automatically  run  the 
006e3  at  the  same  times  the  following  week.  So  hot  water  is 
awlays available when it is needed. If usage pattern changes, the 
SmartPlug adjusts automatically.
Installing the Hot-LinkPlus-e SmartPlug Instant 
Hot Water Control
®
:
Benefits:
Easy to Install: Upgrades the Hot-LinkPlus-e 006e3 circulator to 
“Smart” operation.
Comfort and Convenience: Hot water is available in seconds. No
timers or programming required.
Efficiency: “Smart” mode maximizes hot water comfort and energy
savings.
Reliability:  The  SmartPlug,  when  combined  with  the  006e3 
circulator,  provides  whisper  quiet  operation  and  industry  leading 
electronics for proven performance and dependability.
2. Shut off the hot and cold angle stop valves below the sink.
Figure 5:
Diagram is for reference only
Figure 3:
Figure 4:
SmartPlug Control Options/Features:
“Smart” Mode: When set to Smart mode, the SmartPlug will run
in  Pulse  mode  as  described  below  for  the  first  7  days  of 
operation. During the first 7 days, the SmartPlug monitors and 
records the home's hot water usage pattern. For the following 
7  days,  the  SmartPlug  will  use  the  preceding  week's  usage 
pattern  to  cycle  the  006e3  during  the  recorded  hot  water 
usage  times.    This  process  of  recording  and  repeating  is 
continuous, and automatically adjusts the 006e3 ON times to 
match the household's usage pattern.
“Pulse” Mode: When set to Pulse mode, the SmartPlug will cycle
the  006e3  ON  for  5  minutes,  then  OFF  for  10  minutes  to 
maintain  hot  water  at  all  faucets  and  taps.  It  will  repeat  the 
cycle continuously.
Vacation Mode: After 36 hours of no hot water usage, the
SmartPlug will automatically turn the 006e3 OFF, and will 
automatically restart when hot water usage is detected.
Exercise Function: While in vacation mode, the SmartPlug will
cycle the 006e3 ON for 10 seconds every 7 days to 
prevent corrosion or scale buildup.